12V Battery Runtime Calculator: How Long Will Your Battery Last?

To find how long a 12V battery will run your gear, add up each accessory's amps × hours per day, then divide the battery's usable amp-hours by that total. Example: a fridge drawing 4 A for 12 hours (48 Ah) plus 2 A of camp lights for 4 hours (8 Ah) uses 56 Ah a day. A 100 Ah lithium (LiFePO4) battery rated for 100% usable depth of discharge covers that for about 1.8 days, while a 100 Ah lead-acid battery used to 50% gives 50 Ah, which is less than one day.

The calculator below does that math for up to eight accessories, tells you what battery size you need for the days you want to go without charging, and checks the voltage drop on the cable that feeds a load.

12V Battery Runtime and Cable Voltage Drop Calculator

Take each accessory's current draw (amps) or power (watts) from its label or spec sheet. For a fridge, use the average draw or the hours its compressor actually runs, not the startup peak.

1. Battery bank

Lead-acid: Trojan designs for 20–50%, never past 80%

2. Accessories (daily use)

Leave blank if nothing runs through an inverter

Enter your battery and at least one accessory, then press Calculate runtime.

3. Cable voltage drop check

The calculator doubles it for the return path

Enter amps and cable length to see the voltage drop and the smallest gauge that keeps it under 3% and 10%.

How it works

  • Amps from watts: amps = watts ÷ system voltage (12 or 24 V), from the power equation P = V × I.
  • AC loads: an inverter loses some energy, so the DC amps are divided by the inverter efficiency you enter from its spec sheet. The calculator does not assume a value.
  • Daily use: Ah per day = amps × hours, summed over all accessories. Watt-hours = Ah × system voltage.
  • Usable capacity: rated Ah × number of batteries in parallel × usable depth of discharge. Batteries in parallel add amp-hours at the same voltage.
  • Runtime: usable Ah ÷ Ah per day.
  • Battery size for your trip: Ah per day × days ÷ usable depth of discharge.
  • Voltage drop: V = I × R (Ohm's law), where R = the wire's resistance per 1,000 ft × round-trip length ÷ 1,000. The percentage is the drop divided by the nominal system voltage.

Default depth of discharge. For lead-acid the starting value is 50%. Trojan's user guide says renewable-energy systems are "typically designed for a 20% - 50% depth of discharge" and tells owners not to discharge past 80%, because cycle life falls as discharges get deeper. For LiFePO4 the starting value is 100%, the usable depth of discharge on Battle Born's BB10012 data sheet. Other lithium batteries differ, so enter the figure from your own battery's spec sheet.

Limits. Rated capacity is measured at a slow, steady discharge; Trojan's guide uses the 20-hour rate (C20) in its example. Big loads such as a winch or inverter-powered appliances drain lead-acid batteries faster than the simple math shows. Cold matters too: Trojan states its batteries deliver about 50% of capacity at 0°F (-18°C) and 100% at 80°F (27°C). The voltage drop table is for solid copper at 20°C; stranded cable of the same gauge is close, and resistance rises as the cable heats up. The tool checks voltage drop only, not whether a cable can safely carry the current.

Copper wire resistance used by the calculator

AWGOhms per 1,000 ft at 20°CAWGOhms per 1,000 ft at 20°C
186.38540.2485
164.01620.1563
142.52510.124
121.5881/00.0983
100.99892/00.078
80.62823/00.0618
60.39514/00.049
Source: HyperPhysics (Georgia State University) AWG table, from Floyd, Electric Circuit Fundamentals.

Worked cable example: a 20 A load 10 ft from the battery makes a 20 ft round trip. On 10 AWG that is 20 × 20 × 0.9989 ÷ 1,000 = 0.40 V, or 3.3% of 12 V. On 8 AWG it is 0.25 V, or 2.1%, so 8 AWG is the smallest size that stays under 3%.

3% or 10% voltage drop?

Battle Born's cable-sizing guide, which follows ABYC (American Boat and Yacht Council) practice, says 3% is commonly used for critical circuits and ABYC guidance allows up to 10% for non-critical branch circuits. On a 4x4, treat anything that affects safety or sensitive electronics (fridge compressors, radios, lighting you rely on at night) as the 3% case. The guide also says to size by the round-trip length, positive plus negative, which is why the calculator doubles your one-way length.

Safety: a short circuit on an unfused battery cable can melt insulation and start a fire. Disconnect the negative terminal before working on wiring, fuse every new circuit as the accessory maker specifies, and keep sparks and flames away from batteries, as Trojan's user guide warns.

Sources

More 12V help: why Jeep Wranglers have two batteries, what size winch you need, the Jeep JL no-start troubleshooter and all our free off-road calculators.

Last updated: November 17, 2026. Estimates only; your battery's and accessories' spec sheets take priority. Nothing you enter leaves your browser.

Follow Off-Road Handbook on Google

Like our off-road guides? Add Off-Road Handbook as a Google Preferred Source so our latest Jeep, ATV, UTV, trail, recovery, and off-road troubleshooting articles can appear more often in your Google Search experience.

Add us as a Preferred Source